ECHOLINE® Series Corrosive Media Low Pressure Monitor

LDP ECHOLINE® Corrosive Media incorporates stainless steel sensor technology into ECHOLINE’s® LDP Series allowing for low pressure monitoring of corrosive media systems while maintaining ECHOLINE’s® display, switching, analog output, and “ECHO” functions. This improvement allows the unit to be used in applications that previously could not be monitored with the ECHOLINE® LDP series.

Features

  • Corrosive Media Compatability
  • Optional Voltage or Current Output
  • Ranges from 1″WC to 50″WC differential
  • Ranges from 250 Pascal to 20k Pascal differential
  • Line Pressure up to 100 PSI
  • 3 digit LED display
  • Optional automatic reset function
  • Front Panel setpoint and zero adjustability
  • Auto-Diagnostic Circuit
  • 316L SST and FKM wetted materials
  • 100% Analog Design

Specifications *

Media Clean Dry Air, Inert Gases, Corrosive Media
Type Field Adjustable
Range 0-1″, 5″, 10″, 20″, 50″ WC
0-250, 1000, 2000 Pa
0-10, 20 KP
Proof Pressure ± 14,5 psig ≥ 1″ WC ± 80″ < 1″ WC
Burst Pressure 150 PSIG
Switching Response 1 Sec. to 30 Sec.
Switching Output 1A @ 30 VDC
Switch Point Adjustable 5-95% of Range
Switch Repeatability ± 1.5% F.S.
Input Power 12 to 24 VDC
Analog Output option 4 – 20 mA, 0-10 VDC
Status LED Red/Green
Operating Temp. Range 0-55°C
Display Accuracy ± 1.5% F.S., 0°C to 40°C
Min. Operating Life 5 Million cycles
Approvals UL508, UL991, CE
Warranty 18 Months
Media Connections 1/8″ FNPT Pressure Conn.

* Specifications subject to change

Downloadable Resources

Semiconductor Guide

Pressure, Flow, Level and Temperature Products SAFETY AND PROCESS CONTOL SENSORS

Echoline Low Differential Pressure Monitor Video

Ask an Engineer